Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Indian J Med Res ; 155(5&6): 554-564, 2022.
Artículo en Inglés | MEDLINE | ID: covidwho-2110458

RESUMEN

Background & objectives: The association between hyperglycaemia at admission, diabetes mellitus (DM) status and mortality in hospitalized SARS-CoV-2 infected patients is not clear. The purpose of this study was to determine the relationship between DM, at-admission hyperglycaemia and 28 day mortality in patients admitted with moderate-severe SARS-CoV-2 infection requiring intensive care. Methods: All consecutive moderate-to-severe patients with SARS-CoV-2 infection admitted to the intensive care units (ICUs) over six months were enrolled in this single-centre, retrospective study. The predicators for 28 day mortality were analysed from the independent variables including DM status and hyperglycaemia at-admission. Results: Four hundred and fifty two patients with SARS-CoV-2 were admitted to the ICU, with a mean age of 58.5±13.4 yr, 78.5 per cent being male, HbA1c of 7.2 per cent (6.3-8.8) and 63.7 per cent having DM. Overall, 28 day mortality was 48.9 per cent. In univariate analysis, mortality in diabetes patients was comparable with non-diabetes (47.9 vs. 50.6%, P=0.58), while it was significantly higher in hyperglycaemic group (60.4 vs. 35.8%, P<0.001). In multivariate Cox regression analysis, after adjusting for age, sex and comorbidities, hyperglycaemia at-admission was an independent risk factor of mortality [hazard ratio (HR) 1.45, 95% confidence interval (CI) (1.06-1.99), P<0.05]. Interpretation & conclusions: This study showed that the presence of hyperglycaemia at-admission in critically ill SARS-CoV-2 patients was an independent predictor of 28 day mortality. However, the findings may be susceptible to unmeasured confounding, and more research from prospective studies is required.


Asunto(s)
COVID-19 , Diabetes Mellitus , Hiperglucemia , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , SARS-CoV-2 , Estudios Retrospectivos , Hiperglucemia/complicaciones , Unidades de Cuidados Intensivos , Diabetes Mellitus/epidemiología
2.
Mycoses ; 65(11): 1010-1023, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: covidwho-1896014

RESUMEN

BACKGROUND: COVID-19-associated pulmonary aspergillosis (CAPA) has been widely reported but homogenous large cohort studies are needed to gain real-world insights about the disease. METHODS: We collected clinical and laboratory data of 1161 patients hospitalised at our Institute from March 2020 to August 2021, defined their CAPA pathology, and analysed the data of CAPA/non-CAPA and deceased/survived CAPA patients using univariable and multivariable models. RESULTS: The overall prevalence and mortality of CAPA in our homogenous cohort of 1161 patients were 6.4% and 47.3%, respectively. The mortality of CAPA was higher than that of non-CAPA patients (hazard ratio: 1.8 [95% confidence interval: 1.1-2.8]). Diabetes (odds ratio [OR] 1.92 [1.15-3.21]); persistent fever (2.54 [1.17-5.53]); hemoptysis (7.91 [4.45-14.06]); and lung lesions of cavitation (8.78 [2.27-34.03]), consolidation (9.06 [2.03-40.39]), and nodules (8.26 [2.39-28.58]) were associated with development of CAPA by multivariable analysis. Acute respiratory distress syndrome (ARDS) (2.68 [1.09-6.55]), a high computed tomography score index (OR 1.18 [1.08-1.29]; p < .001), and pulse glucocorticoid treatment (HR 4.0 [1.3-9.2]) were associated with mortality of the disease. Whereas neutrophilic leukocytosis (development: 1.09 [1.03-1.15] and mortality: 1.17 [1.08-1.28]) and lymphopenia (development: 0.68 [0.51-0.91] and mortality: 0.40 [0.20-0.83]) were associated with the development as well as mortality of CAPA. CONCLUSION: We observed a low but likely underestimated prevalence of CAPA in our study. CAPA is a disease with high mortality and diabetes is a significant factor for its development while ARDS and pulse glucocorticoid treatment are significant factors for its mortality. Cellular immune dysregulation may have a central role in CAPA from its development to mortality.


Asunto(s)
COVID-19 , Aspergilosis Pulmonar , Síndrome de Dificultad Respiratoria , COVID-19/complicaciones , COVID-19/epidemiología , Estudios de Cohortes , Cuidados Críticos , Glucocorticoides , Humanos , Aspergilosis Pulmonar/complicaciones , Aspergilosis Pulmonar/epidemiología
3.
Thromb J ; 20(1): 8, 2022 Feb 14.
Artículo en Inglés | MEDLINE | ID: covidwho-1686017

RESUMEN

The authors have done commendable work in exploring the utility of a comprehensive viscoelastic test for assessment of the coagulation cascade in Coronavirus disease 2019 (COVID-19) patients. This article published in your esteemed journal in November 2021 "The evolution of clot strength in critically-ill COVID-19 patients: a prospective observational thromboelastography study" found hypercoagulability in most of the patients at Intensive Care Unit (ICU) admission and also noted a persistently increased fibrin contribution to clot strength. However, we would like to comment upon a few points which may be of importance to the readers.

4.
Indian J Crit Care Med ; 25(12): 1462-1463, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: covidwho-1559741

RESUMEN

How to cite this article: Saran S, Dube M, Azim A. Less Costlier and Emergency Options for Intubation during Coronavirus Disease Times. Indian J Crit Care Med 2021;25(12):1462-1463.

6.
Indian J Crit Care Med ; 25(4): 453-460, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: covidwho-1197617

RESUMEN

Among the various strategies for the prevention of airborne transmission, engineering measures are placed high in the hierarchy of control. Modern hospitals in high-income countries have mechanical systems of building ventilation also called HVAC (heating, ventilation, and air-conditioning) but installation and maintenance of such systems is a challenging and resource-intensive task. Even when the state-of-the-art technology was used to build airborne infection isolation rooms (AIIRs), recommended standards were often not met in field studies. The current coronavirus disease-2019 pandemic has highlighted the need to find cost-effective and less resource-intensive engineering solutions. Moreover, there is a need for the involvement of interdisciplinary teams to find innovative infection control solutions and doctors are frequently lacking in their understanding of building ventilation-related problems as well as their possible solutions. The current article describes building ventilation strategies (natural ventilation and hybrid ventilation) for hospitals where HVAC systems are either lacking or do not meet the recommended standards. Other measures like the use of portable air cleaning technologies and temporary negative-pressure rooms can be used as supplementary strategies in situations of demand surge. It can be easily understood that thermal comfort is compromised in buildings that are not mechanically fitted with HVAC systems, therefore the given building ventilation strategies are more helpful when climatic conditions are moderate or other measures are combined to maintain thermal comfort. HOW TO CITE THIS ARTICLE: Zia H, Singh R, Seth M, Ahmed A, Azim A. Engineering Solutions for Preventing Airborne Transmission in Hospitals with Resource Limitation and Demand Surge. Indian J Crit Care Med 2021;25(4):453-460.

7.
Indian J Crit Care Med ; 25(1): 12-15, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: covidwho-1067881

RESUMEN

Healthcare systems all over the world have been enormously affected by the COVID-19 pandemic. Healthcare workers (HCWs) taking care of these patients need personal protective equipments (PPEs) standardized for full protection from droplets and aerosols carrying viral load to variable distances. There has been a surge of manufacturers supplying these protective gears in India and regulatory agencies have issued technical specifications pertaining to PPEs focusing solely on synthetic blood penetration tests (SBPTs) and keeping the upper limit of non-woven fabric to 95 g/m2 (GSM). These PPE specifications are silent on air permeability (AP) and water/moisture vapor transmission rate (WVTR/MVTR) of the fabric. As a result, most of the PPE kits, despite having appropriate SBPT certifications from regulatory agencies, have extremely poor permeability and breathability. The acceptability of PPEs by HCWs can be vastly improved when the end-users are proactively invited to participate in "comfort testing" of PPEs before getting issuance of certification for marketing. "Field testing" or "end-user trials" in which HCWs don the PPE and assess it for comfort while performing different types of clinical work, e.g., in intensive care units (ICUs), operation theaters, cath labs, etc., also takes into account a hitherto often ignored "human-comfort-factor" that not only enhances the understanding of HCWs about the need for the PPEs but can also motivate them to use it without worrying about discomfort. We hereby propose that comfort fit testing (COmfort and Material Fit is an Obviously Required Test) should be a part of the mandatory testing and certification process for PPE, so that the industry invests wisely in manufacturing PPE kits that are not only certified for fabric but are also tested for comfort factors. How to cite this article: Kapoor A, Baronia AK, Azim A, Agarwal G, Prasad N, Mishra R, et al. Breathability and Safety Testing of Personal Protective Equipment: "Human-comfort" Factor Remains Undefined. Indian J Crit Care Med 2021;25(1):12-15.

8.
Indian J Crit Care Med ; 24(12): 1284-1285, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: covidwho-1055202

RESUMEN

How to cite this article: Siddiqui S, Ahmed A, Azim A. Selecting Journal for Publication in the Era of "Haste Predatory Journals and COVID-19". Indian J Crit Care Med 2020;24(12):1284-1285.

9.
Expert Rev Med Devices ; 17(12): 1265-1276, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: covidwho-933795

RESUMEN

Introduction: The current pandemic of novel Corona Virus Disease 2019 (COVID-19) has created a significant shortage of personal protective equipment (PPE) in many countries of the world, stressing medical services during this crisis. Along with addressing problems of demand and supply mismatch, there also a need to ensure the procurement of high-quality PPEs that provides both safety and comfort to users. The purpose of this article is to review existing standards and recommendations on the technical aspects of PPE. Areas covered: For this review, MEDLINE, Google Scholar, and Research Gate were searched. Studies reporting technical aspects of the components of PPE including mask and respirator, gown, and coverall, gloves, goggles, face shields, or visors, and boots, are included in this review. Expert opinion: The design and materials of PPE needs further research, which might have minimal carriage of infective biological load like the use of antimicrobial repellent finishes along with adequate tensile strength and breathability through the fabric. Respirators should have the least resistance while providing maximum protection; goggles should not have fogging. Also, there is a need of formulating universal technical specifications for medically used PPE and ensuring easy availability of the testing facilities.


Asunto(s)
COVID-19 , Equipo de Protección Personal , Humanos , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Pandemias/prevención & control , Equipo de Protección Personal/normas , Equipo de Protección Personal/provisión & distribución , SARS-CoV-2
10.
Indian J Crit Care Med ; 24(9): 857-862, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: covidwho-883966

RESUMEN

Disposable filtering face piece respirators (FFRs) are usually not approved for routine practice of decontamination and reuse. However, such practice of decontamination and reuse may be needed only as a crisis capacity strategy to ensure continued availability. The current severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) pandemic would help us enlighten about more effective and efficient ways of decontamination and reuse. Based on the limited research available, ultraviolet irradiation, vapors of hydrogen peroxide, and moist heat showed the most promising potential methods to decontaminate FFRs. This article summarizes available research about decontamination of FFRs before reuse. How to cite this article: Singh R, Azim A, Singh N. Should We or Should We Not Reuse Filtering Face Piece Masks? A Review. Indian J Crit Care Med 2020;24(9):857-862.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA